install LCD touch climatronic Panel
Please try the following to activate ""AC"" first
![](http://ueeshop.ly200-cdn.com/u_file/UPAD/UPAD814/2304/photo/7283a37033.png)
1. After installation, you need ODIS debugging code, you need to have it (VAS 5054/VCDS/OBD 11 but the buyer needs to make sure it can modify the code!), otherwise A/C may not work and there is no air-conditioning
2. On the other hand, use ODIS to enter the "08" air conditioning equipment, and find that the "Compressor Magnetic Clutch" is turned on or off, and there will be air-conditioning.
3. On the other hand, connecting the 10-pin and 18-pin T20 plug "maximum plug of air conditioner connector" with a wire in series will also turn on the compressor to produce cold air.
(Connection of wires)
If you don’t understand, please get in touch with the seller, we are very professional and can answer for you
This is adaptation ONLY WITH ORIGINAL VCDS:
"AC Compressor First Run-In" Steps:
Start engine and allow it to Idle.
Adapt flap end stops as described above.
[Basic Settings - 04]
Select "Compressor Run In; Automatic Start" from the drop-down list.
It will show completed, but wait 120 sec (2 Min) and observe the flashing A/C button light on the HVAC panel.
After the Basic Settings has completed, the A/C light will quit flashing and the fault code will clear.
Note: If Basic Settings reports Error the module may need to see an Adaptation change before this can be completed. Go to Adaptation and change the Runtime (or Driving time) for "compressor run-in" basic setting from 120 -to- 120 and save it followed by repeating the procedure.
Tick on off this box. Different combination - will work
Note 1 : If Basic Settings still reports Error change again driving time from 120 to 120 and will find in adaptation onother field with value 60. Do same and change 60 with 60 and then do first run.
INSTALL PROBLEM FAQ :
Q : " MENU " BUTTON PRESS NOT WORKING
A : 5F adaptation -- search 0×01 & 0×02 & 0×03 active all
![](http://ueeshop.ly200-cdn.com/u_file/UPAD/UPAD814/2304/photo/190eed6d6e.jpg)
![](http://ueeshop.ly200-cdn.com/u_file/UPAD/UPAD814/2304/photo/185510f1b5.jpg)
Check Byte 15 bit 2 on or off >> and do first run >> different setting for bit 2 will do first run SUCCES
Long Codding:
00 02 00 04 20 00 00 01 00 04 00 00 00 10 10 04
&&&&
00 02 00 04 20 00 00 01 00 04 00 00 00 10 10 00
INSTALL PROBLEM FAQ :
Q : " MENU " BUTTON PRESS NOT WORKING
A :5F adaptation -- search 0×01 & 0×02 & 0×03 active all